Ford Ecosport: Roof Opening Panel / General Procedures - Power Roof Opening Panel Initialization
Initialization
NOTE:
Until the initialization procedure is complete, the one-touch open and one-touch close function is disabled.
NOTE:
An initialization procedure that was interrupted or not
completed can be started again after cycling the ignition from ON to OFF
and back to ON again.
-
An initialization procedure that was interrupted at the
hard stop can be started again by manually moving the roof opening panel
approximately 2 inches towards the full CLOSED position.
Refer to: Roof Opening Panel Manual Closing (501-17 Roof Opening Panel, General Procedures).
-
Place the ignition switch in the RUN position. For
initializing an existing roof opening panel motor, skip to Step 6.
-
For a new roof opening panel motor, press and hold the
front portion of the control switch until the roof opening panel glass
moves slightly past the full VENT position (approximately 2 mm (0.0787
in)) and returns to the full VENT position.
-
Quickly (within 0.5 second) release, then press and hold
the front portion of the control switch while the roof opening panel
glass move to the full OPEN position and then back to the full CLOSED
position.
-
Release the switch and verify successful initialization
by performing one-touch OPEN and one-touch CLOSE operations.
-
For an existing roof opening panel motor, press and hold
the front portion of control switch until the roof opening panel glass
moves to fully CLOSED position and then release the switch.
-
Press and hold the front portion of the control switch
for approximately 10 seconds until the roof opening panel glass moves
slightly past the full VENT position (approximately 2 mm (0.0787 in))
and returns to the full VENT position.
-
Quickly (within 0.5 second) release, then press and hold
the front portion of the control switch while the roof opening panel
glass moves to the full OPEN position and then back to the full CLOSED
position (movement will start approximately 5 seconds after the switch
is pressed).
-
Release the switch and verify successful initialization
by performing one-touch OPEN and one-touch CLOSE operations.
Adjustment
NOTE:
The front sliding glass panel initialization procedure must
be done when repairs are carried out on the roof opening panel system,
including: any time the roof opening panel motor has been removed, the
roof opening panel glass has been removed or adjusted, or if the roof
opening panel frame has been removed...
Adjustment
Remove the overhead console.
Refer to: Overhead Console (501-12 Instrument Panel and Console, Removal and Installation).
Rotate the retainer clockwise to close the roof opening panel manually...
Other information:
Special Tool(s) /
General Equipment
100-001
(T50T-100-A)
Slide Hammer
100-002
(TOOL-4201-C)
Holding Fixture with Dial Indicator Gauge
205-153
(T80T-4000-W)
Handle
205-990Installer, Axle SealTKIT-2012A-FLTKIT-2012A-ROW
211-061
(T78P-3504-N1)
Remover, Roll Pin
303-D011
(D80L-100-G)
Actuator Pin (Dia 3/16)
..
Special Tool(s) /
General Equipment
Two Leg Puller
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Remove the cap.
Remove the nut.
Torque:
18 lb.ft (25 Nm)
Using a puller, remove the windshield wiper pivot arm.
Us..